/00 The collection

Three product lines,
one envelope standard.

Every Cadence window and door is CSA certified under the harmonized AAMA/WDMA/CSA 101/I.S.2/A440-17 standard and the matching A440S1:19 Canadian supplement. The three lines below differ in frame material, frame depth, and absolute U-factor headroom, not in build quality.

/01 The six profiles

Every profile, in numbers.

Verified to CSA A440.2:19

Swipe the table to compare the six profiles

Build Cadence Hybrid 75 Cadence Alu 75 Cadence Alu 90 Cadence Alu 93 Cadence Alu 142 Cadence Passive
Frame material UPVC core + aluminium cladding Full aluminium (thermal-break) Full aluminium (thermal-break) Full aluminium (passive thermal-break) Full aluminium (thermal-break) Glue-laminated timber + aluminium shell (passive thermal-break)
Frame depth deeper = stronger and warmer 75 mm 75 mm 90 mm 93 mm 142 mm 130 mm
Glazing more panes = warmer and quieter Double or triple Double or triple Double or triple Double or triple Double or triple Triple (standard)
Opening styles Tilt & turn · fixed Tilt & turn · fixed Casement (crank-out) · fixed Tilt & turn · fixed · side-hinged door Sliding Tilt & turn · fixed · side-hinged door
Energy
U-factor (W/m²·K) · best lower = better · range = triple to double 0.85 0.85 to 1.55 1.10 1.10 to 2.05 0.85 0.85 to 1.80 0.85 0.85 to 1.00 1.70 1.70 to 2.45 0.75 0.75 to 0.85
Energy Rating (ER) · best higher = better 40 30 40 40 20 35
Best R-value typical double glazing ≈ R-3 R-6.5 R-5 R-7 R-7 R-3.5 R-7.5
vs. NBC 2020 code code max U-factor = 1.84 54% better 40% better 54% better 54% better 8% better 59% better
ENERGY STAR-ready (triple) *depending on final glazing and zone Yes Fixed only Fixed only Yes No Yes
Passive House certified No No No No No Yes, Uw 0.80
Structure and code
NAFS performance grade higher PG = tougher CW-PG40 CW-PG50 CW-PG40 CW-PG70 CW-PG50 CW-PG50 · PG60 door
Design pressure (psf) peak wind / suction ±40 ±50 ±40 ±70 ±50 ±50 · 60 door
Water tightness (psf) resists driving rain · higher = better 12 12 13 11 · 15 door 15 12 · 15 door
Acoustic laminated glass option available Good · OITC ~31 Good · OITC ~31 Good · OITC ~31 Very good · OITC ~35 Moderate · OITC ~31 Very good · OITC ~35
Common to all Cadence lines German multi-point locking Roto hardware, 10-year warranty on hardware · AkzoNobel powder-coat paint, AAMA-compliant (2603, 2604 or 2605 per project), 10-year finish warranty (20 years with a higher grade) · 20-year warranty on glass units and welded aluminium frames · Low-E argon-filled insulating glass units with warm-edge spacer, EPDM weather seals · CSA certified to AAMA/WDMA/CSA 101/I.S.2/A440 · the Passive line also holds Passive House Institute certification (Uw 0.80 W/m²·K).

Reference only. Not a contract. Energy figures are best-case (triple glazing) per CSA A440.2; ranges span triple-to-double builds. Other glazing, colours, and sizes on request.

Not sure which line?

Share your project, your plans, your specifications, we'll respond quickly.